2nd
numeral |
Degree
of Protection |
| Description |
Definition |
|
0
|
Non-protected |
- |
|
1
|
Protected
vertically falling water drops |
Vertically
falling drops shall have no harmfull effects. |
|
2
|
Protected
vertically falling water drops when the enclosure is tilted
up to 15º |
Vertically
falling drops shall have no harmfull effects when the enclosure
is tilted at any angle up to 15º on either side of the
vertical. |
|
3
|
Protected
against spraying water |
Water
sprayed at an angle of up to 60º on either side of the
vertical shall have no harmful effects. |
|
4
|
Protected
against splashing water |
Water
splashed against the enclosure will enclosure from any direction
shall have no harmful effects. |
|
5
|
Protected
against water jets |
Water
projected in jets against the enclosure will enclosure from
any direction shall have no harmful effects. |
|
6
|
Protected
against powerful water jets |
Water
projected in powerful jets against the enclosure will enclosure
from any direction shall have no harmful effects. |
|
7
|
Protected
against the effects of temporary immersion in water |
Ingress
of water in quantities causing harmful effects shall not be
possible when the enclosure is temporarily immersed in water
under standardised conditions of pressure and time. |
|
8
|
Protected
against the effects of continous immersion in water |
Ingress
of water in quantities causing harmful effects shall not be
possible when the enclosure is continuosly immersed in water
under conditions which shall be agreed between the manufacturer
and the user but which is more severe than for numeral 7. |